0 retailersDetermine the minimum cable cross-section area (CSA) needed for your DC installation based on current draw, cable length, and acceptable voltage drop.
Enter your values and click Calculate to see results.
Undersized cables cause excessive voltage drop, overheating, and potential fire risk. The minimum cable size is calculated from:
Min CSA = (2 × L × I × ρ) / (V × max_drop% / 100)
We then round up to the nearest standard cable size (1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95 mm²).